Browse all practice questions for the Printreading Trade Compentency Practice Test. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

Printreading Trade Compentency Practice Test course image
More practice questions

These questions are part of the practice quiz. Start practicing

  • What type of protection is required for receptacle outlets installed within 6 feet of a sink?
  • The clearance of service drops from the side or bottom of windows designed to open shall not be less than what distance?
  • For determining the maximum number of conductors in boxes, how many conductors are counted for each yoke or strap?
  • If the resistance of a single driven ground rod exceeds 25 ohms, what action must be taken?
  • The term "service-entrance conductors overhead system" includes which of the following?
  • How many cubic feet should securely installed boxes and fittings not exceed if they do not support fixtures or contain devices?
  • What is the minimum length that tap conductors for recessed lighting fixtures must be?
  • What type of jumper is used to bond sections of rigid metal raceway interrupted by an expansion joint?
  • If a 100A load is connected, how should the neutral conductor be sized?
  • Can receptacle outlets located above 5-1/2 feet from the finished floor be counted as required outlets?
  • Plug fuses are never permitted in circuits that exceed what voltage between conductors?
  • The service disconnecting means need not be greater than 30A where there are not more than how many 2-wire branch circuits?
  • Each print in a set of working drawings is a part of a building represented as what type of projection?
  • What is necessary to ensure safety when working with circuits that could create hazards during interruptions?
  • What should the wiring run above heated ceilings and within thermal insulation be derated based on?
  • Are all 125V, 20A receptacles in bathrooms required to have ground-fault circuit interrupter protection?
  • Lighting switches mounted in or on the wall can be located above 6'-7" from the finished floor. True or False?
  • How high must NMS cable (Romex) be protected when passing through a floor?
  • True or False: All junction boxes must be readily accessible.
  • If a 1-1/2" x 4" octagonal box contains a fixture stud and a cable clamp, what is the maximum number of No. 14 conductors permissible?
  • Boxes in electrical installations may have which type of covers?
  • According to the text, how should circuit breakers be loaded when not specifically marked?
  • The conductors of NM cable shall be rated at 90° C but the allowable ampacity of the conductors shall not exceed that of a _______ ° C rated conductor.
  • True or False: Stranded wires No. 10 and smaller may be connected to equipment by means of screws used with terminal plates having upturned lugs.
  • What does AHJ stand for in the context of NEC applications?
  • What might happen if the neutral feeder conductor is undersized?
  • When two switches are mounted on the same strap, should the number of conductors in the box be reduced by one?
  • What type of line is drawn with a series of dashes of equal length?
  • What is the main purpose of the National Electrical Code (NEC)?
  • Is the grounding conductor in a cable assembly required to be insulated for cord and plug connected equipment?
  • What is the proper method for assessing an air conditioning load for a one-family dwelling?
  • Which conductor is essential for ensuring metallic parts remain safe from electrical faults?
  • Receptacles connected to a 30A branch circuit supplying multiple outlets must be rated at a minimum of how many Amperes?
  • What is the critical need for a cutting plane in printreading?
  • What is the minimum free length of conductor at a switch outlet?
  • What is the minimum size for conductors in a service lateral according to the text?
  • Recessed non-Type IC lighting fixtures must maintain a clearance of at least what measurement from combustible material?
  • What is the diameter of conductors needed for service lateral according to the standards?
  • How many Code-Making Panels exist within the NEC?
  • According to the general rule, to what side should a grounding connection not be made for service disconnecting means?
  • What specification must a conductors' insulating material meet when entering a cabinet or box?
  • In general, how should raceways on the exterior surfaces of buildings be arranged?
  • The NEC introduction is followed by how many chapters?
  • What is the purpose of a disconnecting means for stationary motors?
  • An elevation drawing shows what type of planes of a building?
  • NM cable is permitted for both exposed and concealed work in which type of location?
  • Non-current carrying metal parts of cord and plug connected equipment may be grounded by what?
  • What is the maximum voltage permitted between conductors supplying screw shell lampholders in dwelling occupancies?
  • For the installation of equipment grounding conductors, what is essential for safety and compliance?
  • What is the maximum number of No. 14 conductors allowed in a 1-1/2" x 4" octagonal outlet box?
  • Is it true that a No. 6 GEC exposed to physical damage requires metal covering or protection?
  • What is typically the primary focus of the NEC?
  • What is the maximum rating of a cord-and-plug connected appliance on a 20A branch circuit?
  • What is the minimum clearance between the lug and wall of an enclosure for a single No. 4/0 conductor?
  • In combustible walls or ceilings, how far back can the front edge of an outlet box or fitting be set from the finished surface?
  • Which NEC section specifies the requirements for the minimum size of ground conductors?
  • Where should conduit not be connected according to the text?
  • What is the minimum distance receptacle outlets for laundry equipment must be located from their intended appliance location?
  • How many cubic inches is a standard rating for a No.18 fixture wire?
  • For devices with screw shells, which terminal is connected to the grounded conductor?
  • Which of the following does NOT conform to electrical grounding practices?
  • What must be done before making soldered splices?
  • What is the minimum clearance of service drops above roof surfaces?
  • In a 1 phase, 120/240V service, which size should the neutral conductor be if a 100A load is connected across A and B, and a 50A load across A and N?
  • Not more than how many switches at a service location shall be used as the service disconnecting means if they are each permanently marked?
  • In non-residential applications, what is a permissible method of securing overhead conductors?
  • Is a receptacle located in the middle of a dining room floor counted towards fulfilling minimum NEC requirements?
  • When is it necessary to consider the number of conductors in an outlet box?
  • What type of receptacle outlet is mandated for installation on a 15A or 20A branch circuit?
  • What is the minimum clearance required between service drops and windows designed to open?
  • What is the minimum branch circuit rating for a single electric range of over 8-3/4 kVA?
  • What has the Construction Specifications Institute established for writing project specifications?
  • Should metal raceways of an electrical system be bonded or spaced from lightning protection conductors?
  • The NEC is primarily concerned with which aspect of construction?
  • How many switches can be used as service disconnecting means if they are not permanently marked?
  • At what vertical distance are hanging lighting fixtures not permitted from the rim of a bathtub?
  • Which of the following is true regarding Construction Management Panels (CMP)?
  • What is the minimum horizontal distance that hanging lighting fixtures must be from the rim of a bathtub?
  • When connecting 100' of No. 16 fixture wire to a standard 120V circuit, what is the maximum branch-circuit overcurrent protection device allowed?
  • What does an abbreviation typically represent?
  • Can a general purpose branch circuit supply both lighting and appliances?
  • A cartridge fuse which does not have an IC rating marked on its surface shall be considered as having an IC rating of ______.
  • Which division of the CSI format pertains to electrical work?
  • What is a key advantage of using directional boring for installing cables or raceways?
  • What type of protection is required for rooftop receptacle outlets servicing HACR equipment?
  • True or False: Membership on a Code panel, other than the chairperson, is either as an alternate or principal member.
  • The neutral feeder conductor must be capable of carrying what type of load?
  • What rating is required for the service disconnect in a one-family dwelling according to the standards?
  • The screw shell of a plug-type fuseholder should be connected to which side of the circuit?
  • What is the minimum amount of free conductor that should be left at each outlet?
  • What must a branch-circuit switch or circuit breaker be capable of for a permanently connected appliance over 300 VA or 1/8 HP?
  • What should be done with unused openings in boxes and fittings?
  • Conductors other than service conductors should not be installed in what type of service structure?
  • What is the purpose of derating wiring run above heated ceilings?
  • What is the purpose of using an approved depth for outlet boxes?
  • Only power service-drop or overhead service conductors should be attached to a service ______.
  • When installing flexible metal conduit (FMC), what must be provided if the total ground-fault current path is over 6' in length?
  • On which type of plan are cutting planes for section views typically indicated?
  • Which of the following is the correct way the NEC identifies changes from the previous edition?
  • A 4" x 1-1/4" round box has how many cubic inches of fill space area?
  • Service conductors installed as open conductors shall have a clearance of not less than ____' from a window that is designed to be opened.
  • The clearance of service drops above a rooftop is regulated to be not less than how many feet?
  • What is the minimum diameter for stainless steel ground rods unless otherwise listed?
  • True or False: Overhead service conductors must maintain a clearance of at least 10 feet from the ground.
  • What does the NEC stand for?
  • What does the NEC seek to standardize concerning electrical safety?
  • What is the maximum voltage between conductors on a branch circuit supplying luminaries?
  • What is the minimum service disconnect rating for a one-family dwelling?
  • Is the NEC intended to be used as an instructional manual?
  • Wooden supports for boxes in concealed work must be at least what nominal size?
  • A grounded service entrance conductor must not connect to which part of the round boxes?
  • In terms of working drawings, what is the significance of the term "projection"?
  • In which scenarios would it be inappropriate to use aluminum conductors?
  • A ground ring conductor must be buried at least how deep below the earth's surface?
  • In architectural drafting, what is primarily shown in the floor plan?
  • True or False: All prints are drawn to a scale of 1/4" = 1'-0".
  • True or False: The location of water, sewer, gas, and electrical utilities is provided on the plot plan.
  • Disconnecting means for motor-driven appliances over what horsepower shall be located within sight of the motor controller?
  • Which chapters of the NEC apply generally?
  • The branch-circuit rating shall not be less than the noncontinuous load plus what percentage of the continuous load?
  • Cartridge fuses and fuseholders are classified according to which criterion?
  • Are circuit breakers (CBs) that are not marked with an interrupting rating rated at 5000A?
  • What is the minimum size of bare conductor allowed as a concrete-encased electrode?
  • A sheet metal strap ground clamp made of strong sheet metal is permitted for connecting the GEC to the grounding electrode. True or False?
  • In architectural drawings, what is a print?
  • Which section refers to the requirements for buried ground ring conductors?
  • What is the minimum size of a copper equipment grounding conductor (EGC) required for equipment connected to a 40A circuit?
  • Service equipment rated at 1000V or less must be marked for what purpose?
  • What material should not be used to make driven rods for grounding electrodes?
  • What is the unit lighting load for a dwelling unit expressed in VA/sq ft?
  • Is the NEC considered a design specification?
  • For outside branch circuits, what is the required vertical clearance above the roof level from the edge of the roof?
  • When routing several cables through the same hole, at what length must derating factors be applied?
  • True or False: The screw shell of a plug-type fuseholder must be connected to the load side.
  • The required voltage clearance for conductors serving luminaries on a branch circuit should not exceed what?
  • The cutting plane for a floor plan is generally taken how high above the floor being shown?
  • If an electrode has resistance to ground of 25 ohms or less, what is required?
  • Which of these practices is recommended for cabling runs without spacing?
  • In which format is the NEC available?
  • The term "service drops" is associated with which part of an electrical system?
  • A detail is part of which type of view drawn at a larger scale?
  • According to NEC, what is the required VA per square foot for general lighting load in residential occupancies?
  • What type of depth is needed for outlet boxes to avoid damage to conductors?
  • What is the minimum diameter and length of rebar to be installed in concrete at the bottom of a footing?
  • A metal fixture must be grounded if located within what distance of a kitchen sink?
  • What does NEC require for the conductors exposed to physical damage?
  • How far from the edge of a sink must receptacle outlets in a dwelling unit be GFCI-protected?
  • What scale is commonly used for prints in electrical drawings?
  • What does GFCI stand for in the context of electrical safety?
  • The maximum length of overhead service conductors permitted is how many feet?
  • In residential occupancies, the NEC requires how many VA per square foot for the general lighting load?
  • Conductors of what size and larger shall be stranded when installed in raceways?
  • What type of protection is not required for conductors when interrupting the circuit creates a hazard?
  • What is the point of beginning in construction plans?
  • A bare copper grounded service-entrance conductor is permitted to be used in which type of gutter?
  • What is the minimum distance specified for the vertical clearance above a roof level for outside branch circuits?
  • Surface-mounted fluorescent lighting fixtures in a closet must be installed at least how far from storage space?
  • For overhead conductor spans, what shall not be used for support other than temporary holiday wiring?
  • A shallow outlet box can be used if it is not less than what depth?
  • What type of receptacles is specifically mentioned for requiring GFCI protection?
  • How should a circuit breaker with a 60° C terminal be loaded unless otherwise marked?
  • What required voltage marking is placed on service equipment rated at 1000V or less?
  • In a noncombustible ceiling, the front edge of an outlet box may be set back from the surface by how much?
  • A metal underground gas pipe cannot be used as which type of grounding device?
  • What type of wiring must conform to specific installation standards to ensure safety and compliance?
  • What term refers to a graphic representation of an object in printreading?
  • Fittings such as capped elbows and service entrance elbows are classified as which type of fittings?
  • The NEC requires that recessed portions of non-type IC fixture enclosures shall be spaced at least _____" from combustible material.
  • What is the maximum horizontal distance that a point of unbroken wall space can be from a receptacle in a living room of a dwelling unit?
  • What is the minimum diameter for rod type grounding electrodes of zinc unless otherwise listed?
  • What is the minimum insulation rating for conductors installed inside nonmetallic-sheathed cable?
  • Which of the following systems provides redundancy in electrical circuits?
  • When it is impractical to install the service drop below the weatherhead, the point of attachment can be located no farther than ______" from the point of attachment.
  • What is the NEC requirement for circuits for kitchen small appliance load in dwellings?
  • What type of section is taken lengthwise through a building?
  • True or False: The service disconnecting means shall consist of no more than eight switches or circuit breakers?
  • Which statement is true regarding NEC proposals?
  • Conductors connected in parallel in general wiring systems shall be at least No. _______ or larger.
  • Which view of a building is most commonly represented as a section view?
  • Which utility locations are typically indicated on the plot plan?
  • Type NM cable is not required to be connected in a nonmetallic box if secured within how many inches of the box?
  • What is the recommended height for receptacles in living areas according to standard practices?
  • Under what condition is AC cable (BX) permitted to be unsupported?
  • What is the minimum clearance between the lug and wall of an enclosure for a single No.4/0 conductor being terminated, when the conductor does not enter or leave through the opposite wall?
  • An EBJ is permitted outside a raceway when it is not over how long?
  • Water heaters rated over what VA shall have a disconnecting means located within 50 feet and within sight?
  • What is the maximum percentage of the branch circuit ampere rating for a cord-and-plug connected utilization equipment?
  • What best describes a hidden line in architectural drawings?
  • What is the assessed demand load in VA for a 16 kVA electric range?
  • NMS cable (Romex) is not permitted in which type of studio?
  • Which conductor of all 3-wire, DC systems supplying premises wiring shall be grounded?
  • The metal raceway enclosing tap conductors for recessed fixtures shall not be less than _____' nor more than _____' long.
  • How long of overhead service conductors operating at less than 300 V is permitted with 18" of clearance above the roof?
  • What is the term for a shortened form of a word or phrase?
  • What is the smallest overhead service conductor permitted by the NEC for loads other than limited loads of a single branch circuit?
  • What is the maximum resistance to ground for a single electrode, below which a supplemental electrode is not required?
  • The spacing of receptacles in living areas ensures that no point along the available floor line perimeter shall exceed how many inches from a receptacle outlet?
  • What is the maximum number of 2-wire branch circuits allowed under a 30A service disconnecting means?
  • Which of the following is a requirement when mechanically securing splices?
  • If a branch circuit serves kitchen small appliances, how many circuits does NEC require at least?
  • What welding process can the GEC be spliced by?
  • For stationary motors rated at what horsepower or less can disconnecting means be located in the service panel as the branch circuit OCPD?
  • What is required for metal enclosures for grounding electrode conductors (GEC's) from the point of attachment?
  • What is the significance of the resistance measurement in relation to ground rods?
  • In general, the minimum ampacity of ungrounded service-entrance conductors must be at least what?
  • What is the maximum distance EMT shall be securely fastened within of outlet boxes?
  • A receptacle outlet located within 6' of a wet bar sink in a living room must be what type of protection?
  • How far above the earth should aluminum conductors be terminated when used outside as a GEC?
  • What is the minimum area of exposed surface required for a plate electrode?
  • How must parallel conductors in a conduit run be set up?
  • What is the minimum clearance of service drops above a public driveway on other than residential property?
  • True or False: The disconnecting means for a service must connect to both grounded and ungrounded conductors.
  • When using the optional calculation for a dwelling service, loads above the initial 10 kVA are assessed at what percentage?
  • For a sheet metal auxiliary gutter, correction factors shall not apply when the number of current-carrying conductors is how many or less?
  • What is the required distance for a disconnecting means to be located from water heaters rated over 300 VA?
  • What does the term "grounding" mean?
  • What is the significance of the minimum area requirement for plate electrodes?
  • How is material that has changed in the NEC from the previous edition indicated?
  • What is the minimum clearance overhead service conductors must maintain from the ground?
  • To be classified as a grounding electrode, how long must a metal water pipe be in contact with the earth?
  • Which of the following roles do members of the CMP NOT represent?
  • What is the purpose of specifications in construction projects?
  • In which type of location is LFNC not allowed to be used, unless otherwise permitted?
  • On which plans is the location of all exterior walls and interior partitions shown and dimensioned?
  • What is the first step in the Code process?
  • What is the purpose of an equipment bonding jumper in rigid metal raceways?
  • What is the minimum length of a hallway that requires a receptacle outlet?
  • When are double locknuts permitted for bonding with rigid metal raceways?
  • True or False: The NEC is a legal document intended for adoption by governmental bodies.
  • When protecting NMS cable, what is the minimum height above the floor it should be protected to?
  • What is the ampacity rating in degrees Celsius for conductors installed inside AC cable?
  • What is the maximum size of the Grounding Electrode Conductor (GEC) for an AC ungrounded system when it's the sole connection to a made electrode?
  • Where not permanently accessible, nonmetallic-sheathed cable within 5' of a scuttle hole does not require protection. True or False?
  • Which type of view offers detailed information about construction elements?
  • The ampacity of UF cable is determined by conductors rated at what temperature?
  • The cubic inch rating of a No. 10 conductor is what volume?
  • For a one-family dwelling, the air conditioning load is assessed at what percentage?
  • What kind of rating must boxes installed in wet locations have?
  • The cubic inch rating of a No.18 fixture wire is how many cubic inches?
  • Which of the following is not a reason to avoid using NMS cable in specific environments?
  • What defines a detailed plan of a building drawn orthographically?
  • What is required for cables or raceways installed using directional boring equipment?
  • Which regulation specifies the safe use of grounding conductors?
Subscribe

Get the latest from Passetra

You can unsubscribe at any time. Read our privacy policy